1.
Rev. Assoc. Paul. Cir. Dent ; 63(3): 191-194, maio-jun. 2009. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-534474

RESUMO

O objetivo deste estudo foi avaliar a quantidade de chumbo existente no papel preto que envolve as películas radiográficas utilizadas na odontologia. Papéis pretos de películas expostas aos raios-X e de películas novas foram submetidos à decomposição por ácido nítrico a 50%, as soluções obtidas foram analisadas por absorção atômica para determinação de chumbo. Os papéis também foram analisados por MEV acoplado ao sistema EDS, a fim de confirmar a presença de chumbo. Os resultados evidenciaram alta concentração de chumbo no papel de películas submetidas aos raios-X, atingindo uma média de 991 + ou - 321 ppm, enquanto que no papel novo não foi encontrado chumbo. Estes resultados evidenciaram a necessidade de tratar previamente o papel antes do descarte, além de alertar os profissionais sobre os cuidados no manuseio do papel, sendo imprescindível a utilização de equipamentos de proteção a fim de evitar a contaminação por chumbo.


The objective of this study was to evaluate the amount of lead present in black papers that involve radiographic films used in dentistry. Black papers of films exposed to X-ray and new films were submitted to the decomposition by 50% nitric acid, and the obtained solutions were analyzed by atomic absorption for the determination of lead dose. Papers were also analyzed by SEM coupled to the EDS system in order to confirm the lead presence. The results evidenced high lead concentration in the film papers submitted to X-ray, reaching an average of 991 + ou - 321 ppm. No lead was found in new papers. These results showed the need of previously treatment of the black paper before discarding them. Professionals should be careful on the black paper handling and also use protection equipments in order to avoid lead contamination.


Assuntos
Chumbo/toxicidade , Meio Ambiente , Filme para Raios X/efeitos adversos
3.
Odonto (Säo Bernardo do Campo) ; 13(25): 90-99, jan.-jun. 2005. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-428156

RESUMO

O objetivo deste estudo foi avaliar a influência da sensibilidade do filme radiográfico intrabucal e experiência do examinador na detecção de lesão periapical artificialmente produzida. Antes e após a confecção de elsão periapical em mandíbula seca, foram realidas radiografias periapicais com filmes de diferentes sensibilidades: E (Kodak Insight, processado anualmente), D (Kodak Ultra-spedd) e E (Agfa M2 Confort). As radiografias obtidas foram analisadas sobre o negatoscópio, por dois diefrentes examinadores, que utilizaram uma escala de cinco níveis para indicar a presença ou não da lesão óssea. plotadas as curvas ROC, os resultados demonstarram que, para o examinador 1, os três filmes exibiram curvas idênticas valor ROC = 1). Para o examinador 2, as curvas ROC demonstraram um melhor desempenho para o filme Ultra-sped (valor ROC = 0,88), seguido pelo M2 Confort (valor ROC = 0,76) e Insight (valor ROC = 0,50)


Assuntos
Filme para Raios X/efeitos adversos , Tecido Periapical , Radiografia Dentária/efeitos adversos , Tolerância a Radiação , Radiologia
4.
Health Devices ; 30(8): 273-310, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11544777

RESUMO

Film is an effective means for capturing diagnostic information. However, film images cannot be easily integrated into a digital communication system. Thus, as the number of healthcare facilities moving toward a digital work-flow increases, so too does the interest in digital x-ray (DX) systems, which produce images as collections of digital data, rather than as static films. In this first part of our two-part series on DX systems, we present an overview of DX technology, we review the cost factors to consider when deciding whether to invest in DX technology, we offer guidance to help facilities determine which type of system--cassette or cassetteless--will best meet their needs, and we evaluate cassette DX systems from four suppliers. Part 2 of our series, which features an evaluation of cassetteless DX systems, will be published later this year. Our testing of DX systems identifies whether a system can provide at least the same amount of diagnostic information as a screen-film system while significantly increasing the efficiency of operations. We found all the evaluated systems to be effective, but we rank the systems from two suppliers above the others because their user interfaces allow easier and more efficient operation.


Assuntos
Intensificação de Imagem Radiográfica/instrumentação , Intensificação de Imagem Radiográfica/normas , Análise Custo-Benefício , Desenho de Equipamento , Humanos , Intensificação de Imagem Radiográfica/economia , Intensificação de Imagem Radiográfica/métodos , Sistemas de Informação em Radiologia/instrumentação , Tecnologia Radiológica/economia , Tecnologia Radiológica/instrumentação , Filme para Raios X/efeitos adversos , Filme para Raios X/economia
6.
Rev. Fac. Odontol. Bauru ; 7(3/4): 39-45, jul.-dez. 1999. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-298405

RESUMO

Analisou-se a utilizaçäo das Densidades Radiográfica (DR) e Densidade Radiográfica invertida (DRi), obtidas pelo uso do programa de imagem Adobe Photoshop 4.0, para substituir a Densidade Óptica (DO) na avaliaçäo dos filmes e soluçöes de processamento. Utilizamos tiras de filme TMS-1 que após serem expostas no sensitômetro MRA por 0,5 segundo, foram processadas na soluçäo RP X-Omat da Kodak na processadora automática CRONEX T4, na temperatura de 34ºC. Utilizamos o fotodensitômetro MRA para avaliar a Densidade Óptica (DO). Para analisar a DR e DRi, as tiras de filmes foram escaneadas (Scanjet HP 4C/T), e utilizamos o programa Adobe Photoshop 4.0, para obtençäo dos resultados (DR e DRi). Esses dados serviram para avaliar a soluçäo de processamento radiográfico quanto a sua atividade e degradaçäo. Pelos resultados, concluímos que a Densidade Óptica, Densidade Radiográfica e Densidade Radiográfica invertida tiveram resultados semelhantes variando com valores mais altos quando a soluçäo era nova e valores mais baixos quando da degradaçäo da soluçäo. Ainda podemos concluir que as leituras das tiras realizadas no fotodensitômetro podem ser substituídas pelas leituras digitalizadas com a vantagem de ser mais objetiva, de diminuir o tempo para obtençäo dos dados de Densidade Radiográfica e Densidade Radiográfica invertida


Assuntos
Filme para Raios X/efeitos adversos , Filme para Raios X/classificação , Filme para Raios X/normas , Radiografia Dentária Digital/classificação , Radiografia Dentária Digital/instrumentação , Radiografia Dentária Digital/métodos , Interpretação de Imagem Radiográfica Assistida por Computador , Processamento de Sinais Assistido por Computador/instrumentação , Software/classificação , Software/normas
7.
Acta Radiol ; 39(3): 332-6, 1998 May.
Artigo em Inglês | MEDLINE | ID: mdl-9571955

RESUMO

PURPOSE: X-ray film processing is associated with pollution from photo chemicals and from the water used to rinse the film. We tested a new processing system that was aimed at reducing both environmental pollution and costs through the use of solid photo chemicals and recirculation of the rinsing water. MATERIAL AND METHODS: Before and after the installation of new mixers for the solid chemicals and a system for recirculating the rinsing water, we measured: water consumption, processor function quality, image quality, archivability, and the waste-silver content in the rinsing water. RESULTS: After the installation of a simple system for recirculating the rinsing water, there was an 88% reduction in water and film consumption as shown in the amount of water/m2 film that was used. At the same time, the release of silver-contaminated rinsing water directly into the sewers was stopped. Image quality remained unchanged. Archivability was assessed at more than 100 years. The solid photo chemicals and specially designed mixers proved efficient and provided a stable image quality of high standard. It was thus possible to reduce the risk of pollution from the transportation, storage and handling of liquid chemicals. CONCLUSION: A simple recirculation system for the rinsing water would significantly reduce water consumption and eliminate contamination of the environment by silver. The on-site preparation of photo chemicals proved viable and reduced the costs of film processing.


Assuntos
Poluição Ambiental/prevenção & controle , Fotoquímica/métodos , Poluição Química da Água/prevenção & controle , Filme para Raios X , Fotoquímica/economia , Filme para Raios X/efeitos adversos , Filme para Raios X/economia
9.
Rev. Fac. Odontol. Bauru ; 5(3/4): 37-44, jul.-dez. 1997. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-222589

RESUMO

O presente trabalho visou demonstrar a necessidade do controle de infecçäo cruzada em procedimentos radiográficos intrabucais, além de elaborar e testar um sistema de controle de infecçäo cruzada por meio de algumas substâncias de fácil acesso em nosso país. Foram testados como desinfetantes das superfícies dos filmes periapicais as soluçöes: álccol 77 por cento v/v; hipoclorito de sódio 2 por cento; água oxigenada a 3 por cento; e glutaraldeído 2 por cento. A amostra foi composta por 80 filmes que, após remoçäo da cavidade bucal, foram divididos em 7 grupos experimentais, contendo 10 filmes cada, e um grupo controle, também composto por 10 filmes, onde näo se utilizou nenhum método de desinfecçäo. Para os 7 grupos experimentais, realizou-se a desinfecçäo dos filmes segundo dois métodos: imersäo em soluçäo por 5 minutos e fricçäo com gaze esterilizada embebida na soluçäo por 30 segundos, com exceçäo de glutaraldeído, testado apenas para o método de imersäo. A efetividade das soluçöes empregadas foi avaliada pela semeadura de todos os filmes, tanto do grupo controle quanto do grupo experimental, na superfície de placas de ágar sangue (PROBAC), a fim de detectar a densidade de crescimento bacteriano. Os filmes, após serem submetidos à análise microbiológica, foram processados pelo método tempo/temperatura para verificar se as soluçöes usadas alteravam ou näo a imagem radiográfica. Das soluçöes testadas, o glutaraldeído 2 por cento, álcool 77 por cento v/v e hipoclorito de sódio 2 por cento se mostraram efetivos na desinfecçäo dos filmes, näo se observando crescimento bacteriano sobre as placas semeadas para ambos os métodos de desinfecçäo, enquanto que a água oxigenada, permitiu o crescimento de colônias bacterianas sobre as mesmas. Em todos os grupos testados näo ocorreu alteraçäo da imagem radiográfica após o processamento, indicando que as soluçöes empregadas näo prejudicaram a qualidade das imagens obtidas


Assuntos
Humanos , Masculino , Feminino , Desinfetantes/farmacologia , Filme para Raios X/efeitos adversos , Etanol/farmacologia , Glutaral/farmacologia , Infecções , Medicina Bucal , Radiografia Dentária , Hipoclorito de Sódio/farmacologia
13.
In. Freitas, Leonidas de. Radiologia bucal: técnicas e interpretaçäo. Säo Paulo, Pancast, 1992. p.313-29, ilus.
Monografia em Português | LILACS, BBO - Odontologia | ID: lil-250630
16.
Bauru; s.n; 1991. 166 p. ilus, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: lil-222731

RESUMO

O presente estudo teve por finalidade estudar a degradaçäo das soluçöes reveladora e fixadora Kodak, prontas para o uso, processando filmes Kodak Ektaspeed (EP-21), com câmara escura portátil, sob duas condiçöes de experimentaçäo: com as soluçöes em recipientes de plástico opaco e com tampas (soluçöes protegidas), e recipientes de vidro (soluçöes desprotegidas, simulando as condiçöes de sua execuçäo em consultórios odontológicos. Os dados obtidos das radiografias produzidas pela comparaçäo da densidade óptica, densidade de volume de prata e análise subjetiva, proporcionaram resultados que permitiram-nos constatar que as soluçöes protegidas tiveram um período de utilizaçäo menor que as soluçöes desprotegidas (28 e 35 dias). O número médio de radiografias produzidas até a degradaçäo das soluçöes foi de 104 para as protegidas e de 130 radiografias para a soluçäo desprotegida. Ao longo do experimento näo foram sentidas alteraçöes na degradaçäo das soluçöes em funçäo da variaçäo da temperatura ambiente, do pH, da cor, como também da influência do ar e da iluminaçäo


Assuntos
Radiografia Dentária/efeitos adversos , Radiografia Dentária/instrumentação , Filme para Raios X/efeitos adversos , Ar/análise , Cor , Concentração de Íons de Hidrogênio/efeitos da radiação , Diagnóstico Bucal/métodos , Iluminação/efeitos adversos , Efeitos da Radiação , Temperatura
18.
Bauru; s.n; 1987. 176 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: lil-222783

RESUMO

O presente trabalho teve a finalidade de analisar, através de um novo método de medida, a quantidade de prata metálica na emulsäo de filmes radiográficos. O método proposto baseia-se na determinaçäo da densidade de volume de prata reduzida em funçäo das variáveis: exposiçäo aos raios X, tipo de filmes e de soluçöes de processamento. Utilizamos para controle e comparaçäo as densidades ópticas obtidas em um fotodensitômetro, bem como a confecçäo de seus respectivos traçados característicos, para cada tipo de filme radiográfico (Kodak e Agfa) e processamento (Kodak e Inodon). A determinaçäo da densidade de volume ocupado pela prata metálica baseia-se nos princípios de morfometria. Utilizamos portanto, para sua obtençäo, de uma ocular com retículo de 25 pontos em um microscópio de luz, com objetiva de 97X. A densidade de prata da emulsäo foi estimada pelo método de Chalkley, da seguinte maneira: no microscópio, após a focalizaçäo do filme radiográfico, contaram-se os pontos coincidentes com os gräos de prata. Todas as faixas de exposiçäo em cada um dos filmes radiográficos processados, nos dois diferentes tipos de soluçöes, foram analisados, quarenta diferentes acampos, com um total de 1000 pontos. A comparaçäo do método proposto com o já consagrado da densitometria óptica e respectivos traçados característicos, foi realizada através das análises estatística e gráfica. Primeiro foi demonstrado, por um programa de ajuste de polinômios, que as variáveis apresentavam uma linearidade de primeiro grau; em seguida foram calculados os coeficientes de correlaçäo e as retas de regressäo da densidade de volume em relaçäo à densidade óptica. Os coeficientes de correlaçäo apresentavam níveis bastantes elevados, fato este confirmado graficamente pela similariedade dos traçados característicos obtidos pelos dois métodos de medida. Pelos resultados alcançados, chegamos à conclusäo que o método proposto, também é válido para a verificaçäo do efeito dos raios X sobre a emulsäo de filmes radiográficos periapicais, podendo ser utilizado portanto, nas pesquisas que visam analisar o comportamento dos filmes e processamento radiográfico


Assuntos
Prata/análise , Prata/normas , Filme para Raios X/normas , Dosimetria Fotográfica/métodos , Radiografia Dentária/normas , Filme para Raios X/efeitos adversos